| Function | |
| DC voltage DCV | u221a |
| AC voltage ACV | u221a |
| DC current DCA | u221a |
| AC current ACA | u221a |
| Resistor / Diode / On-Off Test / Capacitor | u221a |
| Frequency F | u221a |
| Square wave output | u221a |
| NCV | u221a |
| Full unit symbol | u221a |
| Backlight manual/Auto off | u221a |
| True RMS measurement | u221a |
| Temperature | u221a |
| Flashlight lighting | u221a |
| Accuracy Range | 6000counts | Resolution |
| 6V | ± | 0.001V |
| 60V | 0.01V | |
| 600V | 0.1V | |
| 1000V | ± | 1V |
| Accuracy Range | 6000counts | Resolution |
| 6V | ± | 0.001V |
| 60V | 0.01V | |
| 600V | 0.1V | |
| 750V | ± | 1V |
| Accuracy Range | 6000counts | Resolution |
| 60A | ± | 0.01A |
| 600A | 0.1A |
| Accuracy Range | 6000counts | Resolution |
| 60A | 0.01A | |
| 600A | 0.1A |
| Accuracy Range | 6000counts | Resolution |
| 600Ω | ± | 0.1Ω |
| 6kΩ | ± | 1Ω |
| 60kΩ | 10Ω | |
| 600kΩ | 100Ω | |
| 6MΩ | 1kΩ | |
| 40MΩ | ± | 10kΩ |
| Range | display value | test condition |
|
Products related to this item
Loading related products...
❮
❯
Videos for similar product
Loading product videos...
❮
❯
Tools, Industrial & Scientific Ranking
![]() ![]() | Diode forward voltage drop | Forward DC current is about 1mA, open circuit voltage is about 3V |
| The buzzer sounds long and the resistance of the test is less than (50u00b120) u03a9. | Open circuit voltage is about 3V, press "SELECT" for two-speed function switching |
| Accuracy Range | 6000counts | Resolution |
| 60nF | u00b1 | 10pF |
| 600nF | 100pF | |
| 6uF | 1nF | |
| 60uF | 10nF | |
| 600uF | 100nF | |
| 6mF | u00b1 | 1uF |
| 30mF | 10uF |
| Accuracy Range | 6000counts | Resolution |
| 10Hz | u00b1 | 0.01Hz |
| 100Hz | 0.1Hz | |
| 1kHz | 1Hz | |
| 10kHZ | 10Hz | |
| 100kHz | 100Hz | |
| 1MHz | 1kHz | |
| 10MHz | 10kHz |
| Accuracy Range | 6000counts | Resolution |
| (-20-1000 )u2103 | u00b1 | 1u2103 |
| (0-1832 )u2109 | u00b1 | 1u2109 |





A part of the review has been auto-translated.
* 3 weeks shipment to Israel (good).
Note that it does not use the std Israel post-office but use U-SPEED. Beware if order value is above 75$ !! (this item is less)
* The item working OK. I bought it for it's clamp DC current so I compared clamp DC current to Fluke wire current - see pictures.
Above 2A, deviation was less then 2% and get improved as the current increased.
Some comparative tests, little bit shifted on DC A. You have to go through all the points to get to the amps from the OFF position.
Tips:For questions about your order, place of delivery, product discount, taxation, delivery time, warranty, shipping, payment, exchange rate, and other questions unrelated to the product, please contact customer service.
A part of the QA has been auto-translated.